How radiation kills
Direct and indirect damage, D10 values and what changes resistance. Why product does not become radioactive within the energy limits set for e-beam and X-ray, and why BIs are not used for release.
Radiation
Part 6R Radiation
How radiation kills, then gamma, e-beam and X-ray, the irradiator and dosimetry. Written for a maker that owns and runs its own e-beam line. It builds on 2A and opens with a 2-minute recall of it.

Where it sits
05 sterilize · you are here
Before it: 2A Designing for sterility, in the design stage. Next: 6R2. After Part 6 comes Part 7, Packaging, storage and shelf life. See the pricing.

Direct and indirect damage, D10 values and what changes resistance. Why product does not become radioactive within the energy limits set for e-beam and X-ray, and why BIs are not used for release.
The three sources compared on penetration, dose rate and throughput, and how cobalt-60 supply is pushing X-ray.

How dose is set by timer, conveyor speed or beam settings. The calibration program, radiation safety and preventive maintenance.
Routine and reference dosimeters, and why the dosimetry system is calibrated before any validation dose counts.

The cobalt-60 source rack and pool, the shielding maze, the tote conveyor, source decay and replenishment, and the interlocks.
The accelerator, scan horn and conveyor, and the X-ray converter target: energy, current, scan width and conveyor speed.

Calibration to a national standard, transfer-standard curves, and temperature and dose-rate corrections. How to spot a flawed curve in your own dosimetry calibration records.

The user requirements sterility assurance (SA) writes for the line, the dosimetry system the site now runs itself, and what SA approves at OQ before the line is released for product dose mapping. Shielding, interlocks and the radiation licence or registration are reviewed, and stay with radiation safety. Case: your site's first in-house e-beam line.

12 questions in 15 min: 8 from this module and 4 from earlier ones. Practice, for your own check.
Radiation path lessons are in the Tenets + Radiation path. Lessons marked All access come only with all access.
Standards named in this module: ISO 11137-1:2025 (lesson 6R1.1).
The video is the lesson: 12 min for most, 15 min for the gamma plant lesson.
Its last scene hands off to an explore page: about 5 min, about 10 min for the 15-min lessons.
The module ends with a quiz: 12 questions in 15 min, 8 from this module and 4 from earlier ones.
Before it
The modalities compared and the plants walked. This module opens with a 2-minute recall of it.
See module 2ATwo full modules, plus a free 20-question starting check.